{"id":848,"date":"2021-02-25T14:03:37","date_gmt":"2021-02-25T14:03:37","guid":{"rendered":"https:\/\/artec.kopdigitaal-dev.nl\/product\/c-therm-trident-thermal-conductivity\/"},"modified":"2021-02-25T14:03:37","modified_gmt":"2021-02-25T14:03:37","slug":"c-therm-trident-thermal-conductivity","status":"publish","type":"product","link":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/","title":{"rendered":"C-Therm Trident thermal conductivity"},"content":{"rendered":"<p>Thermal conductivity range: 0.01 to 500 W \/ mK<br \/>\nThermal diffusivity range: 0.01 to 300mm\u00b2 \/ s<\/p>\n<p><strong>The system includes:<\/strong><br \/>\n&#8211; Trident Thermal Property Analyzer Electronic Control Unit<br \/>\n&#8211; Standard Laptop with Windows 10\u00ae Operating System<br \/>\n&#8211; Small Volume Test Cell<br \/>\n&#8211; Pelican \u2122 Transport case<br \/>\n&#8211; C-Therm TC3 \u2122 Software License<\/p>\n<p><strong>Modified Transient Plane Source<br \/>\n<\/strong>1 \u00d7 MTPS Sensor<br \/>\n&#8211; Thermal conductivity: 0.01 to 500 W \/ mK (Max-k)<br \/>\n&#8211; Temperature: -50\u00baC to 200\u00baC (optional up to 500\u00baC)<br \/>\n&#8211; Test materials: solids, liquids, powders, pastes<br \/>\nReference Material: Expanded Polystyrene (EPS), LAF6720, Pyrex, Pyroceram, Phosphate Bronze, Copper<\/p>\n<p><strong>Transient Plane Source<\/strong><br \/>\n3 \u00d7 Flex TPS (hot disc) Kapton based sensors<br \/>\n&#8211; Thermal conductivity: 0.03 to 500 W \/ mK<br \/>\n&#8211; Temperature: -50\u00baC to 80\u00baC (optional up to 300\u00baC)<br \/>\nReference material: stainless steel 304 (x2)<\/p>\n<p><strong>Transient Line Source<\/strong><br \/>\n1 \u00d7 150mm TLS Needle Probe<br \/>\n&#8211; Thermal conductivity: 0.1 to 6 W \/ mK<br \/>\n&#8211; Temperature: -55\u00baC to 200\u00baC<br \/>\n&#8211; Test material: viscous \/ viscous liquids, non-consolidated solids, molten polymers<br \/>\nReference material: Glycerine<\/p>\n<p>Climate cabinet is available separately.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Thermal conductivity range: 0.01 to 500 W \/ mK<br \/>\nThermal diffusivity range: 0.01 to 300mm\u00b2 \/ s<\/p>\n<p><strong>The system includes:<\/strong><br \/>\n&#8211; Trident Thermal Property Analyzer Electronic Control Unit<br \/>\n&#8211; Standard Laptop with Windows 10\u00ae Operating System<br \/>\n&#8211; Small Volume Test Cell<br \/>\n&#8211; Pelican \u2122 Transport case<br \/>\n&#8211; C-Therm TC3 \u2122 Software License<\/p>\n<p><strong>Modified Transient Plane Source<br \/>\n<\/strong>1 \u00d7 MTPS Sensor<br \/>\n&#8211; Thermal conductivity: 0.01 to 500 W \/ mK (Max-k)<br \/>\n&#8211; Temperature: -50\u00baC to 200\u00baC (optional up to 500\u00baC)<br \/>\n&#8211; Test materials: solids, liquids, powders, pastes<br \/>\nReference Material: Expanded Polystyrene (EPS), LAF6720, Pyrex, Pyroceram, Phosphate Bronze, Copper<\/p>\n<p><strong>Transient Plane Source<\/strong><br \/>\n3 \u00d7 Flex TPS (hot disc) Kapton based sensors<br \/>\n&#8211; Thermal conductivity: 0.03 to 500 W \/ mK<br \/>\n&#8211; Temperature: -50\u00baC to 80\u00baC (optional up to 300\u00baC)<br \/>\nReference material: stainless steel 304 (x2)<\/p>\n<p><strong>Transient Line Source<\/strong><br \/>\n1 \u00d7 150mm TLS Needle Probe<br \/>\n&#8211; Thermal conductivity: 0.1 to 6 W \/ mK<br \/>\n&#8211; Temperature: -55\u00baC to 200\u00baC<br \/>\n&#8211; Test material: viscous \/ viscous liquids, non-consolidated solids, molten polymers<br \/>\nReference material: Glycerine<\/p>\n<p>Climate cabinet is available separately.<\/p>\n","protected":false},"featured_media":641,"template":"","meta":[],"product_brand":[],"product_cat":[1153,1157,1159,1160,3529],"product_tag":[],"class_list":["post-848","product","type-product","status-publish","has-post-thumbnail","product_cat-insulation","product_cat-nonwoven-en","product_cat-polymers","product_cat-rubber-en","product_cat-thermal-properties","pa_merk-c-therm-en","pa_norm-astm-d7984-en","pa_norm-gb-t-32064-en","pa_norm-iso-22007-2-en","pa_toepassing-automotive-en","pa_toepassing-effusivity","pa_toepassing-heat-conduction","pa_toepassing-thermal-conductivity","pa_toepassing-thermal-properties","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>C-Therm Trident thermal conductivity - Artec Testnology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"C-Therm Trident thermal conductivity - Artec Testnology\" \/>\n<meta property=\"og:description\" content=\"Thermal conductivity range: 0.01 to 500 W \/ mK Thermal diffusivity range: 0.01 to 300mm\u00b2 \/ s  The system includes: - Trident Thermal Property Analyzer Electronic Control Unit - Standard Laptop with Windows 10\u00ae Operating System - Small Volume Test Cell - Pelican \u2122 Transport case - C-Therm TC3 \u2122 Software License  Modified Transient Plane Source 1 \u00d7 MTPS Sensor - Thermal conductivity: 0.01 to 500 W \/ mK (Max-k) - Temperature: -50\u00baC to 200\u00baC (optional up to 500\u00baC) - Test materials: solids, liquids, powders, pastes Reference Material: Expanded Polystyrene (EPS), LAF6720, Pyrex, Pyroceram, Phosphate Bronze, Copper  Transient Plane Source 3 \u00d7 Flex TPS (hot disc) Kapton based sensors - Thermal conductivity: 0.03 to 500 W \/ mK - Temperature: -50\u00baC to 80\u00baC (optional up to 300\u00baC) Reference material: stainless steel 304 (x2)  Transient Line Source 1 \u00d7 150mm TLS Needle Probe - Thermal conductivity: 0.1 to 6 W \/ mK - Temperature: -55\u00baC to 200\u00baC - Test material: viscous \/ viscous liquids, non-consolidated solids, molten polymers Reference material: Glycerine  Climate cabinet is available separately.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/\" \/>\n<meta property=\"og:site_name\" content=\"Artec Testnology\" \/>\n<meta property=\"og:image\" content=\"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/\",\"url\":\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/\",\"name\":\"C-Therm Trident thermal conductivity - Artec Testnology\",\"isPartOf\":{\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png\",\"datePublished\":\"2021-02-25T14:03:37+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#primaryimage\",\"url\":\"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png\",\"contentUrl\":\"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png\",\"width\":1000,\"height\":1000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/artec-testapparatuur.nl\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/artec-testapparatuur.nl\/en\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"C-Therm Trident thermal conductivity\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/artec-testapparatuur.nl\/en\/#website\",\"url\":\"https:\/\/artec-testapparatuur.nl\/en\/\",\"name\":\"Artec Testnology\",\"description\":\"Your link to quality\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/artec-testapparatuur.nl\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"C-Therm Trident thermal conductivity - Artec Testnology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/","og_locale":"en_US","og_type":"article","og_title":"C-Therm Trident thermal conductivity - Artec Testnology","og_description":"Thermal conductivity range: 0.01 to 500 W \/ mK Thermal diffusivity range: 0.01 to 300mm\u00b2 \/ s  The system includes: - Trident Thermal Property Analyzer Electronic Control Unit - Standard Laptop with Windows 10\u00ae Operating System - Small Volume Test Cell - Pelican \u2122 Transport case - C-Therm TC3 \u2122 Software License  Modified Transient Plane Source 1 \u00d7 MTPS Sensor - Thermal conductivity: 0.01 to 500 W \/ mK (Max-k) - Temperature: -50\u00baC to 200\u00baC (optional up to 500\u00baC) - Test materials: solids, liquids, powders, pastes Reference Material: Expanded Polystyrene (EPS), LAF6720, Pyrex, Pyroceram, Phosphate Bronze, Copper  Transient Plane Source 3 \u00d7 Flex TPS (hot disc) Kapton based sensors - Thermal conductivity: 0.03 to 500 W \/ mK - Temperature: -50\u00baC to 80\u00baC (optional up to 300\u00baC) Reference material: stainless steel 304 (x2)  Transient Line Source 1 \u00d7 150mm TLS Needle Probe - Thermal conductivity: 0.1 to 6 W \/ mK - Temperature: -55\u00baC to 200\u00baC - Test material: viscous \/ viscous liquids, non-consolidated solids, molten polymers Reference material: Glycerine  Climate cabinet is available separately.","og_url":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/","og_site_name":"Artec Testnology","og_image":[{"width":1000,"height":1000,"url":"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/","url":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/","name":"C-Therm Trident thermal conductivity - Artec Testnology","isPartOf":{"@id":"https:\/\/artec-testapparatuur.nl\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#primaryimage"},"image":{"@id":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#primaryimage"},"thumbnailUrl":"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png","datePublished":"2021-02-25T14:03:37+00:00","breadcrumb":{"@id":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#primaryimage","url":"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png","contentUrl":"https:\/\/artec-testapparatuur.nl\/wp-content\/uploads\/2021\/02\/C-Therm-Trident-thermische-geleiding.png","width":1000,"height":1000},{"@type":"BreadcrumbList","@id":"https:\/\/artec-testapparatuur.nl\/en\/product\/c-therm-trident-thermal-conductivity\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/artec-testapparatuur.nl\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/artec-testapparatuur.nl\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"C-Therm Trident thermal conductivity"}]},{"@type":"WebSite","@id":"https:\/\/artec-testapparatuur.nl\/en\/#website","url":"https:\/\/artec-testapparatuur.nl\/en\/","name":"Artec Testnology","description":"Your link to quality","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/artec-testapparatuur.nl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/product\/848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/media\/641"}],"wp:attachment":[{"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/media?parent=848"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/product_brand?post=848"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/product_cat?post=848"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/artec-testapparatuur.nl\/en\/wp-json\/wp\/v2\/product_tag?post=848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}